VK-T06 in ultra-thin fireproof coatings application

Fireproof coatings through to adding different amounts of VK-T06, test the fire performance and inorganic layer by XRD and EDS analysis, we can draw the following conclusions:
(A) in the ultra-thin fireproof coatings by adding an appropriate amount of titanium dioxide VK-T06 can significantly improve the combustion of carbonaceous coating layer strength, but it will add too much suppression fire retardant coating expansion;
(2) by adding at the fireproof coatings nano-titanium dioxide VK-T06 can promote the formation of titanium pyrophosphate, while allowing a more compact and uniform white inorganic layer, thereby improving the fire retardant coating time.